Vzduchem chlazený kompenzační kondenzátor pro středofrekvenční pece je pro slévárny, které kupují funkční tavení, ne samostatný díl. Kapacita, výkon, kmitočet a chlazení se řídí kovem a sítí.
Zheng Zhou Li Zhao Electric Furnace Co., Ltd. dodá tuto položku samostatně nebo v kompletní středofrekvenční lince: zdroj, kondenzátory, cívka, jho, pec, sklápění a chlazení.
Technická data
| Model | UN (kV) | QN (kvar) | FN (kHz) | CN (µF) | IN (A) | Groups | L (mm) | B (mm) | H (mm) | I (mm) | II (mm) | b (mm) | Weight (kg) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| RFM0.75-500-2.5S | 0.75 | 500 | 2.5 | 56.59 | 666.7 | 4 | 303 | 120 | 250 | 105 | 87 | 55 | 14.0 |
| RFM0.75-500-10S | 0.75 | 500 | 10.0 | 14.15 | 666.7 | 4 | 303 | 120 | 195 | 105 | 87 | 55 | 12.0 |
| RFM0.75-640-4S | 0.75 | 640 | 4.0 | 45.27 | 853.3 | 4 | 303 | 142 | 250 | 105 | 87 | 55 | 16.5 |
| RFM0.75-640-8S | 0.75 | 640 | 8.0 | 22.64 | 853.3 | 4 | 303 | 120 | 225 | 105 | 87 | 55 | 16.0 |
| RFM0.75-640-10S | 0.75 | 640 | 10.0 | 18.11 | 853.3 | 4 | 303 | 120 | 210 | 105 | 87 | 55 | 12.5 |
| RFM0.75-1000-0.5S | 0.75 | 1000 | 0.5 | 565.9 | 1333 | 8 | 440 | 165 | 445 | 85 | 82 | 75 | 49.0 |
| RFM0.75-1000-1S | 0.75 | 1000 | 1.0 | 282.9 | 1333 | 6 | 336 | 142 | 430 | 80 | 75 | 60 | 31.0 |
| RFM20.75-1000-1S | 0.75 | 1000 | 1.0 | 282.9 | 1333 | 6 | 336 | 165 | 350 | 80 | 75 | 75 | 29.5 |
| RFM0.75-1000-1S | 0.75 | 1000 | 1.0 | 282.9 | 1333 | 6 | 336 | 165 | 385 | 80 | 75 | 75 | 32.0 |
| RFM0.75-1000-2.5S | 0.75 | 1000 | 2.5 | 113.2 | 1333 | 6 | 303 | 142 | 335 | 68 | 72 | 60 | 22.0 |
| RFM1.0-1000-0.5S | 1.0 | 1000 | 0.5 | 318.3 | 1000 | 6 | 440 | 165 | 385 | 125 | 87 | 75 | 40.0 |
| RFM1.0-1000-1S | 1.0 | 1000 | 1.0 | 159.2 | 1000 | 6 | 336 | 142 | 350 | 80 | 75 | 60 | 25.0 |
| RFM1.0-1000-2S | 1.0 | 1000 | 2.0 | 79.58 | 1000 | 6 | 336 | 142 | 335 | 80 | 75 | 60 | 24.0 |
| RFM1.0-1000-2.5S | 1.0 | 1000 | 2.5 | 63.66 | 1000 | 6 | 303 | 142 | 335 | 68 | 72 | 60 | 21.5 |
| RFM1.2-750-0.5S | 1.2 | 750 | 0.5 | 165.8 | 625 | 6 | 336 | 142 | 430 | 80 | 75 | 60 | 30.5 |
| RFM1.2-1000-0.5S | 1.2 | 1000 | 0.5 | 221.0 | 833.3 | 6 | 440 | 165 | 335 | 125 | 87 | 75 | 35.0 |
| RFM1.2-1000-0.7S | 1.2 | 1000 | 0.7 | 157.9 | 833.3 | 6 | 336 | 165 | 335 | 80 | 75 | 75 | 27.5 |
| RFM1.2-1200-0.7S | 1.2 | 1200 | 0.7 | 189.5 | 1000 | 6 | 336 | 165 | 385 | 80 | 75 | 75 | 31.0 |
| RFM1.2-1250-0.65S | 1.2 | 1250 | 0.65 | 212.5 | 1042 | 6 | 440 | 165 | 335 | 125 | 87 | 75 | 35.0 |
| RFM1.2-1400-0.7S | 1.2 | 1400 | 0.7 | 221.0 | 1167 | 6 | 440 | 165 | 335 | 125 | 87 | 75 | 35.0 |
| RFM1.2-1500-0.5S | 1.2 | 1500 | 0.5 | 331.6 | 1250 | 6 | 440 | 165 | 495 | 125 | 87 | 75 | 48.0 |
| RFM1.2-2000-0.5S | 1.2 | 2000 | 0.5 | 442.1 | 1667 | 8 | 440 | 205 | 435 | 85 | 82 | 95 | 56.0 |
| RFM1.2-2000-0.65S | 1.2 | 2000 | 0.65 | 340.1 | 1667 | 8 | 440 | 165 | 495 | 85 | 82 | 75 | 48.0 |
| RFM1.4-1000-0.5S | 1.4 | 1000 | 0.5 | 162.4 | 714.3 | 6 | 440 | 165 | 335 | 125 | 87 | 75 | 35.0 |
| RFM1.4-1000-1S | 1.4 | 1000 | 1.0 | 81.2 | 714.3 | 6 | 336 | 142 | 335 | 80 | 75 | 60 | 24.0 |
| RFM1.4-2000-0.5S | 1.4 | 2000 | 0.5 | 324.8 | 1429 | 6 | 440 | 205 | 435 | 125 | 87 | 95 | 54.0 |
| RFM1.6-2000-0.5S | 1.6 | 2000 | 0.5 | 248.7 | 1250 | 6 | 440 | 205 | 460 | 125 | 87 | 95 | 54.5 |
| RFM21.6-2000-0.5S | 1.6 | 2000 | 0.5 | 248.7 | 1250 | 6 | 440 | 205 | 435 | 125 | 87 | 95 | 52.0 |
| RFM1.7-1500-0.25S | 1.7 | 1500 | 0.25 | 330.4 | 882.4 | 4 | 440 | 205 | 610 | 170 | 120 | 95 | 71.0 |
| RFM1.7-2000-0.5S | 1.7 | 2000 | 0.52 | 220.3 | 1176 | 6 | 440 | 205 | 435 | 125 | 87 | 95 | 52.0 |
| RFM1.7-1000-0.15S | 1.7 | 1000 | 0.15 | 367.1 | 588.2 | 4 | 440 | 205 | 610 | 170 | 120 | 95 | 72.0 |
| Item | Value |
|---|---|
| Installation altitude | Not above 1000 m |
| Site | No severe shock, corrosive gas, steam or explosive dust |
| Cooling-water inlet | Not above 30°C / 86°F |
| Cooling-water flow | At least 4 L/min below 1000 kvar; at least 6 L/min at 1000 kvar and above |
| Overvoltage | 1.1 × UN for 4 hours |
| Continuous current | Not above 1.35 × IN |
| Catalog standards | JB/T 7110-93 and IEC 60110-1 (1998) |
| Suffix S | Water-cooled. No S suffix on the air-cooled construction shown on the same sheet |
| Model code | RFM, voltage kV, kvar, frequency kHz, S = water-cooled |
| US standard | Applies to |
|---|---|
| IEC 60110-1 | Power capacitors for induction heating — the catalog rating standard |
| IEEE 18 | US shunt-capacitor standard buyers ask to see beside IEC 60110-1 |
| IEEE 519 | Harmonic duty seen by the capacitor bank |
| ASTM B187 | Copper bus bar in the capacitor rack |
Every figure in these tables is taken from the factory sheets in the product folder and is written in English. 1 metric ton = 1.102 US short tons. Power-supply ratings can still be negotiated to the customer requirement, as the sheet itself states. American standards are the US specifications normally requested with this equipment.
Vlastnosti
- Návrh podle kovu, rychlosti tavení a napětí sítě
- Samostatně nebo jako část kompletního tavicího systému
- Exportní balení pro Evropu, USA a Brazílii
- Rozměry a připojení podle výkresu pece
Konstrukce
- Kapacita, napětí, kmitočet, rozměry a připojení lze udělat podle návrhu pece. Pošlete výkres nebo provozní data.
Princip funkce
Toto zařízení patří do stejné linky jako zdroj, kondenzátorová baterie, cívka, jho, těleso pece a chlazení. Nabídka může pokrýt jednu položku nebo celou linku.
Aplikace
Ocel, litina, nerez, měď, hliník, slitina hliníku, mosaz a další neželezné kovy.
Zařazení do kompletního systému
Toto zařízení patří do stejné linky jako zdroj, kondenzátorová baterie, cívka, jho, těleso pece a chlazení. Nabídka může pokrýt jednu položku nebo celou linku.
Přizpůsobení
Kapacita, napětí, kmitočet, rozměry a připojení lze udělat podle návrhu pece. Pošlete výkres nebo provozní data.
Katalogové listy


Otázky před nabídkou
Lze parametry upravit?
Ano. Kapacita, napětí, kmitočet, průřez a připojení vycházejí z výkresu pece a kovu.
Co je potřeba pro nabídku?
Kapacita, kov, teplota, rychlost tavení, pracovní hodiny, vstupní napětí, kmitočet pokud je znám, sklápění a chladicí voda. Výkres pomůže.
Dodáte jeden stroj, nebo celý systém?
Obojí. Náhradní cívka, jho, kondenzátor nebo věž se nabízejí samostatně. Nová linka jako kompletní systém.
Které kovy lze tavit?
Ocel, litina, nerez, měď, hliník, slitina hliníku, mosaz a další neželezné kovy. Vyzdívka a kmitočet se řídí slitinou.
Potvrdíte katalogové údaje před výrobou?
Ano. Listy na této stránce jsou tovární katalog pro výběr. Nabídka uvádí hodnoty, které se vyrobí.