Luchtgekoelde compensatiecondensator voor middenfrequentieovens is voor gieterijen die een werkende smelt kopen, niet een los onderdeel. Capaciteit, vermogen, frequentie en koeling volgen het metaal en het net.
Zheng Zhou Li Zhao Electric Furnace Co., Ltd. levert dit onderdeel los of in de complete middenfrequentielijn: voeding, condensatoren, spoel, juk, oven, kantelen en koeling.
Technische gegevens
| Model | UN (kV) | QN (kvar) | FN (kHz) | CN (µF) | IN (A) | Groups | L (mm) | B (mm) | H (mm) | I (mm) | II (mm) | b (mm) | Weight (kg) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| RFM0.75-500-2.5S | 0.75 | 500 | 2.5 | 56.59 | 666.7 | 4 | 303 | 120 | 250 | 105 | 87 | 55 | 14.0 |
| RFM0.75-500-10S | 0.75 | 500 | 10.0 | 14.15 | 666.7 | 4 | 303 | 120 | 195 | 105 | 87 | 55 | 12.0 |
| RFM0.75-640-4S | 0.75 | 640 | 4.0 | 45.27 | 853.3 | 4 | 303 | 142 | 250 | 105 | 87 | 55 | 16.5 |
| RFM0.75-640-8S | 0.75 | 640 | 8.0 | 22.64 | 853.3 | 4 | 303 | 120 | 225 | 105 | 87 | 55 | 16.0 |
| RFM0.75-640-10S | 0.75 | 640 | 10.0 | 18.11 | 853.3 | 4 | 303 | 120 | 210 | 105 | 87 | 55 | 12.5 |
| RFM0.75-1000-0.5S | 0.75 | 1000 | 0.5 | 565.9 | 1333 | 8 | 440 | 165 | 445 | 85 | 82 | 75 | 49.0 |
| RFM0.75-1000-1S | 0.75 | 1000 | 1.0 | 282.9 | 1333 | 6 | 336 | 142 | 430 | 80 | 75 | 60 | 31.0 |
| RFM20.75-1000-1S | 0.75 | 1000 | 1.0 | 282.9 | 1333 | 6 | 336 | 165 | 350 | 80 | 75 | 75 | 29.5 |
| RFM0.75-1000-1S | 0.75 | 1000 | 1.0 | 282.9 | 1333 | 6 | 336 | 165 | 385 | 80 | 75 | 75 | 32.0 |
| RFM0.75-1000-2.5S | 0.75 | 1000 | 2.5 | 113.2 | 1333 | 6 | 303 | 142 | 335 | 68 | 72 | 60 | 22.0 |
| RFM1.0-1000-0.5S | 1.0 | 1000 | 0.5 | 318.3 | 1000 | 6 | 440 | 165 | 385 | 125 | 87 | 75 | 40.0 |
| RFM1.0-1000-1S | 1.0 | 1000 | 1.0 | 159.2 | 1000 | 6 | 336 | 142 | 350 | 80 | 75 | 60 | 25.0 |
| RFM1.0-1000-2S | 1.0 | 1000 | 2.0 | 79.58 | 1000 | 6 | 336 | 142 | 335 | 80 | 75 | 60 | 24.0 |
| RFM1.0-1000-2.5S | 1.0 | 1000 | 2.5 | 63.66 | 1000 | 6 | 303 | 142 | 335 | 68 | 72 | 60 | 21.5 |
| RFM1.2-750-0.5S | 1.2 | 750 | 0.5 | 165.8 | 625 | 6 | 336 | 142 | 430 | 80 | 75 | 60 | 30.5 |
| RFM1.2-1000-0.5S | 1.2 | 1000 | 0.5 | 221.0 | 833.3 | 6 | 440 | 165 | 335 | 125 | 87 | 75 | 35.0 |
| RFM1.2-1000-0.7S | 1.2 | 1000 | 0.7 | 157.9 | 833.3 | 6 | 336 | 165 | 335 | 80 | 75 | 75 | 27.5 |
| RFM1.2-1200-0.7S | 1.2 | 1200 | 0.7 | 189.5 | 1000 | 6 | 336 | 165 | 385 | 80 | 75 | 75 | 31.0 |
| RFM1.2-1250-0.65S | 1.2 | 1250 | 0.65 | 212.5 | 1042 | 6 | 440 | 165 | 335 | 125 | 87 | 75 | 35.0 |
| RFM1.2-1400-0.7S | 1.2 | 1400 | 0.7 | 221.0 | 1167 | 6 | 440 | 165 | 335 | 125 | 87 | 75 | 35.0 |
| RFM1.2-1500-0.5S | 1.2 | 1500 | 0.5 | 331.6 | 1250 | 6 | 440 | 165 | 495 | 125 | 87 | 75 | 48.0 |
| RFM1.2-2000-0.5S | 1.2 | 2000 | 0.5 | 442.1 | 1667 | 8 | 440 | 205 | 435 | 85 | 82 | 95 | 56.0 |
| RFM1.2-2000-0.65S | 1.2 | 2000 | 0.65 | 340.1 | 1667 | 8 | 440 | 165 | 495 | 85 | 82 | 75 | 48.0 |
| RFM1.4-1000-0.5S | 1.4 | 1000 | 0.5 | 162.4 | 714.3 | 6 | 440 | 165 | 335 | 125 | 87 | 75 | 35.0 |
| RFM1.4-1000-1S | 1.4 | 1000 | 1.0 | 81.2 | 714.3 | 6 | 336 | 142 | 335 | 80 | 75 | 60 | 24.0 |
| RFM1.4-2000-0.5S | 1.4 | 2000 | 0.5 | 324.8 | 1429 | 6 | 440 | 205 | 435 | 125 | 87 | 95 | 54.0 |
| RFM1.6-2000-0.5S | 1.6 | 2000 | 0.5 | 248.7 | 1250 | 6 | 440 | 205 | 460 | 125 | 87 | 95 | 54.5 |
| RFM21.6-2000-0.5S | 1.6 | 2000 | 0.5 | 248.7 | 1250 | 6 | 440 | 205 | 435 | 125 | 87 | 95 | 52.0 |
| RFM1.7-1500-0.25S | 1.7 | 1500 | 0.25 | 330.4 | 882.4 | 4 | 440 | 205 | 610 | 170 | 120 | 95 | 71.0 |
| RFM1.7-2000-0.5S | 1.7 | 2000 | 0.52 | 220.3 | 1176 | 6 | 440 | 205 | 435 | 125 | 87 | 95 | 52.0 |
| RFM1.7-1000-0.15S | 1.7 | 1000 | 0.15 | 367.1 | 588.2 | 4 | 440 | 205 | 610 | 170 | 120 | 95 | 72.0 |
| Item | Value |
|---|---|
| Installation altitude | Not above 1000 m |
| Site | No severe shock, corrosive gas, steam or explosive dust |
| Cooling-water inlet | Not above 30°C / 86°F |
| Cooling-water flow | At least 4 L/min below 1000 kvar; at least 6 L/min at 1000 kvar and above |
| Overvoltage | 1.1 × UN for 4 hours |
| Continuous current | Not above 1.35 × IN |
| Catalog standards | JB/T 7110-93 and IEC 60110-1 (1998) |
| Suffix S | Water-cooled. No S suffix on the air-cooled construction shown on the same sheet |
| Model code | RFM, voltage kV, kvar, frequency kHz, S = water-cooled |
| US standard | Applies to |
|---|---|
| IEC 60110-1 | Power capacitors for induction heating — the catalog rating standard |
| IEEE 18 | US shunt-capacitor standard buyers ask to see beside IEC 60110-1 |
| IEEE 519 | Harmonic duty seen by the capacitor bank |
| ASTM B187 | Copper bus bar in the capacitor rack |
Every figure in these tables is taken from the factory sheets in the product folder and is written in English. 1 metric ton = 1.102 US short tons. Power-supply ratings can still be negotiated to the customer requirement, as the sheet itself states. American standards are the US specifications normally requested with this equipment.
Kenmerken
- Waarden afgestemd op metaal, smeltsnelheid en netspanning
- Los geleverd of in het complete smeltsysteem
- Exportverpakking voor Europa, de Verenigde Staten en Brazilië
- Maten en aansluitingen volgens de oventekening
Opbouw
- Capaciteit, spanning, frequentie, maten en aansluitingen kunnen de ovenstudie volgen. Stuur de tekening of de bedrijfsgegevens.
Werkingsprincipe
Dit onderdeel staat in dezelfde lijn als de voeding, de condensatorbank, de spoel, het juk, het ovenlichaam en de koeling. Een offerte kan één deel of de hele lijn dekken.
Toepassingen
Staal, gietijzer, roestvast staal, koper, aluminium, aluminiumlegering, messing en ander non-ferro.
Integratie in het complete systeem
Dit onderdeel staat in dezelfde lijn als de voeding, de condensatorbank, de spoel, het juk, het ovenlichaam en de koeling. Een offerte kan één deel of de hele lijn dekken.
Maatwerk
Capaciteit, spanning, frequentie, maten en aansluitingen kunnen de ovenstudie volgen. Stuur de tekening of de bedrijfsgegevens.
Catalogusbladen


Vragen vóór de offerte
Kan het vermogen worden aangepast?
Ja. Capaciteit, spanning, frequentie, doorsnede en aansluiting volgen de oventekening en het metaal.
Wat is nodig voor een offerte?
Capaciteit, metaal, temperatuur, smeltsnelheid, bedrijfsuren, ingangsspanning, frequentie indien bekend, kantelen en koelwater. Een tekening helpt.
Levert u één machine of het complete systeem?
Beide. Een reservespoel, juk, condensator of koeltoren kan los worden aangeboden. Een nieuwe lijn als compleet systeem.
Welke metalen kunnen worden gesmolten?
Staal, gietijzer, roestvast staal, koper, aluminium, aluminiumlegering, messing en ander non-ferro. Bekleding en frequentie volgen de legering.
Bevestigt u de cataloguscijfers vóór de bouw?
Ja. De bladen op deze pagina zijn de fabriekscatalogus voor de keuze. De offerte noemt de waarden die worden gebouwd.