FBT Series Closed-Circuit Cooling Tower

FBT Closed-Circuit Cooling Tower

The FBT series is a closed-circuit cooling tower for furnace coil water, power-supply water and capacitor water. The process water stays inside a coil and does not touch outside air, so the furnace circuit stays clean.

Technical Data

FBT closed-circuit cooling tower — factory sheet. FBI-175-II and FBI-200-II are printed on the same sheet.
ModelWater 37–32°C (m³/h)Water 40–32°C (m³/h)Water 55–35°C (m³/h)Fan power (kW)Air flow (m³/s)Spray pump (kW)Spray water (m³/h)Inlet/outletWorking pressure (MPa)Weight (kg)Size L×W×H (mm)
FBT-10010065451.1330.752280×40.3532502410×3000×4620
FBT-12512581562.2421.52680×40.3535452410×5220×4620
FBT-15015095673421.52680×40.3537852410×5220×4620
FBT-175175109783501.54480×80.3543002410×3000×4620
FBT-200200130904.4632.24480×80.3547502410×3550×4620
FBT-2502501621124.4562.25280×80.553002410×3550×4620
FBT-3003001901324.4822.252100×120.562002410×3550×4620
FBT-350350221154682388100×120.570002410×3550×4620
FBT-4004002601806126488100×80.681002410×2510×4620
FBT-45045029120081265.5132100×80.687002410×2510×4620
FBT-500500320227121265.5132100×80.693502140×2510×4620
FBT-60-II60392712257.52280×40.328002410×2510×4620
FBT-70-II70453116254×22280×40.3529502410×2510×4620
FBT-80-II80523616335.5×226100×40.3532502410×2510×4620
FBT-100-II100554524335.5×226100×40.3534202410×2510×4620
FBT-125-II125815824427.5×226100×40.3537802410×2510×4620
FBT-150-II150966724424×44480×80.3541502410×2510×4620
FBI-175-II1751097832484×44480×80.443502410×2910×4620
FBI-200-II2001309032485.5×44480×80.549502410×2910×4620
FBT series points — factory sheet
ItemCatalog statement
Process waterSoft water in a closed coil, no contact with outside air, no scaling in the furnace circuit
Open pondNot used on the process-water side
Spray sectionCollects spray water; the coil stays clean
Fan driveLow-power motor with a gear reducer
Cold climateAntifreeze heating, cooling and heating in one tower
Energy statement on the sheetAbout 30% less than comparable domestic towers, small fan and high water flow
American standards
US standardApplies to
CTI STD-201Cooling Technology Institute thermal performance for US towers
NEMA MG 1Fan and pump motors
NFPA 70 (NEC)Tower and pump electrical supply

Every figure in these tables is taken from the factory sheets in the product folder and is written in English. 1 metric ton = 1.102 US short tons. Power-supply ratings can still be negotiated to the customer requirement, as the sheet itself states. American standards are the US specifications normally requested with this equipment.

Key features

  • Closed loop: no scaling inside the furnace cooling circuit
  • No open pond on the process-water side
  • Antifreeze duty for cold climates
  • Low-power spray pump and fan, with speed control on the tower
  • Catalog models from the FBT-60 / FBT-100 class upward

Construction

  • Heat-exchange coil, spray section, fan, basin and the furnace pump set.

Working principle

Hot furnace water passes through the tower coil. Spray water and air take the heat away. The furnace water returns at the temperature the coil and the power supply require.

Applications

Steel, cast iron, stainless steel, copper, aluminum, aluminum alloy, brass and other non-ferrous metals.

Complete system integration

This equipment sits in the same line as the power supply, the capacitor bank, the induction coil, the magnetic yoke, the furnace body and the cooling system. A quotation can cover one item or the full line.

Customization

Capacity, voltage, frequency, dimensions and connection layout can be made to the furnace design. Send the drawing or the duty data below.

Catalog sheets

FBT Closed-Circuit Cooling Tower
Factory catalog sheet. Selection only until the quotation confirms the rating.

Questions before a quotation

Can the rating be customized?

Yes. Capacity, voltage, frequency, tube size and connection layout follow the furnace drawing and the metal.

What do you need for a quotation?

Furnace capacity, metal, melting temperature, melting rate, working hours, input voltage, frequency if known, tilting method and cooling-water conditions. A drawing helps.

Do you supply a single machine or the complete system?

Both. A spare coil, yoke, capacitor or cooling tower can be quoted alone. A new foundry line is quoted as a complete system.

Which metals can be melted?

Steel, cast iron, stainless steel, copper, aluminum, aluminum alloy, brass and other non-ferrous metals. The lining and the frequency follow the alloy.

Will you confirm the catalog numbers before manufacture?

Yes. The sheets on this page are the factory catalog for selection. The quotation states the rating that will be built.